Sensors, PLCs, and SCADA on one data layer — with edge gateways, historians, and OEE dashboards that make machine behavior visible to the people running the plant. Engineered for brownfield plants
Get data out of mixed-vintage equipment — PLCs, CNC controllers, meters, and standalone sensors — and onto one normalized stream.
On-site compute that collects, filters, and buffers machine data, so the line keeps recording when the uplink drops out.
Availability, performance, and quality computed from machine signals rather than manual logs — visible on the floor and in the office.
Machine telemetry stored at the resolution engineers need, with retention tiers and query access for analysis and reporting.
Thresholds, trends, and models over vibration, temperature, current, and cycle data to flag equipment drifting out of normal.
Close the loop between floor and office by linking machine events to work orders, inventory, quality records, and ERP.
Live machine status, cycle counts, and stoppages across every line, replacing whiteboards and end-of-shift paperwork.
Instrument critical assets, build a normal-behavior baseline, and trend toward failure indicators before scheduling logic changes.
Sub-metering across lines, compressors, and utilities to attribute consumption to assets, shifts, and production volume.
Continuous logging of temperature, humidity, and process parameters, with tamper-evident records available for audits.
Tie each batch or serial number to the machines, settings, operators, and materials involved in producing it.
Roll standardized metrics from several sites into one view, while each plant keeps local autonomy and local buffering.
Integration built for mixed-vintage brownfield equipment rather than assuming a fleet replacement.
Local buffering designed so a dropped uplink costs you connectivity, not the production record.
Availability, performance, and quality computed the same way on every line and every shift.
Designed to move data north from the control network without opening a path back into it.
Walk the floor to catalogue controllers, protocols, network layout, and which signals actually exist today.
Instrument a single line end to end, prove the data path, and validate metric definitions with the people who use them.
Extend to the remaining lines and sites, then connect machine events to MES, maintenance, and ERP workflows.
Hand over dashboards and runbooks, tune alarms against real noise, and layer analytics once the data is trusted.
How we connect machines, respect OT boundaries, and roll out across plants.
Usually, yes. Machines with a PLC or controller can often be read over OPC UA, Modbus, or a vendor protocol. Genuinely unconnected assets get retrofit sensors — current clamps, vibration pucks, proximity and cycle counters — mounted without altering the machine. We survey the floor first and tell you which assets fall into which category before quoting a rollout.
Our manufacturing industry page describes outcomes for the sector as a whole, including supply chain, workforce, and MES. This page is the engineering layer beneath the shop-floor half of it: getting signals off machines, moving them safely across the OT/IT boundary, storing them, and turning them into OEE and condition metrics.
No. The standard pattern is a one-way northbound flow: an edge gateway on the OT side reads from controllers and publishes outward through a controlled boundary, with no inbound path back into the control network. Where remote support is needed, it runs through a brokered, logged session rather than a permanent tunnel.
The edge gateway buffers locally and forwards once the link returns, so the production record has no gap. Floor-facing dashboards served from the gateway keep working during an outage, since operators need the display most when other things are already going wrong.
That is the approach we recommend. A single-line pilot proves the protocol path, the metric definitions, and the operator workflow at a fraction of the cost of a plant-wide commitment — and it surfaces the awkward assets early, while the scope is still small enough to change.
You do, and we write it down. OEE is only comparable if availability, performance, and quality use one agreed definition — planned versus unplanned stops, micro-stoppage thresholds, how rework is treated. We facilitate that agreement between production and maintenance during the pilot, then encode it once so every line reports the same way.
Start with one line. We survey the assets, prove the data path, and agree the metric definitions before anything scales.